Product Detail
Essential details
Product Introduction:
A newly designed solar and energy storage hybrid inverter, capable to install in on-grid solar, off-grid solar and back-up systems. Hybrid enables a programmable and schedulable smart solar energy storage system to help increase your solar energy self-consumption rate, protect your home appliances from grid shortage, and balance your energy usage strategy to save energy bill.

Product Specification:
Model #
|
SE300-5048
|
|||
General parameters
|
||||
Size(mm)
|
595*539*205 | |||
Net/ Gross Weight(kg)
|
32/35kgs | |||
Installation method
|
Wall-mounted | |||
Ambient temperature
|
-30~60℃ | |||
Relative humidity
|
0~95% | |||
Working elevation
|
<3000 | |||
Protection level
|
IP65 | |||
Standby power consumption(W)
|
<5W | |||
Cooling method
|
Natural cooling | |||
Noise(dB)
|
<25 | |||
Display
|
LCD&APP | |||
Communication
|
CAN,WIFI,RS485,RS232 | |||
Warranty
|
5 | |||
DC switch
|
integrated |
PV input
|
||||
Max DC input power
|
6000W
|
|||
Rated DC input power(W)
|
5000W
|
|||
Maximum DC input voltage(V)
|
580
|
|||
MPPT Voltage range(V)
|
125~550
|
|||
Start-up Voltage(V)
|
125
|
|||
Max input current(A)
|
11/11
|
|||
MPPT channels
|
2
|
|||
DC input channels
|
2
|
Battery
|
||||
Battery types
|
Lead acid, lithium battery.etc.
|
|||
Input voltage(V)
|
48(40~70)
|
|||
Maximum charge and discharge electric power (W)
|
5000W
|
|||
Maximum charge and discharge current(A)
|
110
|
|||
battery capacity(AH)
|
50~200
|
|||
charging method
|
2-stage / 3-stage
|
On-grid Output
|
||||
Maximum input/output power(W)
|
6000W
|
|||
Maximum input/output current(A)
|
20
|
|||
UPS(Resistive load)
|
Yes
|
|||
Rated output voltage(V)
|
220/230 180V~270Vac
|
|||
Rated output frequency(Hz)
|
50/60
|
|||
Power factor
|
0.99, 0.8 lead ~ 0.8 lag
|
|||
THDi
|
<3%
|
|||
Grid type
|
Single phase
|
Off-grid Output
|
||||
Maximum output power(W)
|
5000W/4600W(DE)
|
|||
The output voltage(V)
|
230Vac/220Vac (±2%)
|
|||
Rated output frequency(Hz)
|
50/60
|
|||
THDv
|
<3%
|
|||
Switch off network switching time
|
<5ms
|
|||
Overload capability
|
5s@>150%;10s@110%~150%
|
Effectiveness
|
||||
Maximum efficiency
|
97.6%
|
|||
European efficiency
|
97.2%
|
|||
MPPT efficiency
|
99.9%
|
|||
Battery off-grid output efficiency
|
94.7%
|
Certificates and standards
|
||||
Grid standard
|
VDE-AR-N 4105,VDE0126-1-1,G83/2,G59/3,AS4777.2/.3
|
|||
Safety
|
IEC62109-1&-2,AS3100,IEC62040-1
|
|||
Electromagnetic Compatibility
|
EN61000-6-1,EN61000-6-2,EN61000-6-3
EN61000-6-4, EN61000-3-11,EN61000-3-12, |